JH (High Rate) series is specially designed for heavy load discharge applications with 8 to 15 years of design life in float service. By using strong grids and specially designed active material the JH series offers stable performance during high current discharge. The JH series offers 30% more power output than the standard range. Suitable for UPS/EPS systems where high current loads are required.
Model | Nominal Voltage (V) | Capacity | Dimension | Weight | Terminal | ||||||||
(Ah) | Length | Width | Height | Total Height | Kg | Lbs | |||||||
mm | inch | mm | inch | mm | inch | mm | inch | ||||||
JH12-38W | 12 | 9 | 151 | 5.94 | 65 | 2.56 | 94 | 3.70 | 100 | 3.94 | 2.50 | 5.51 | F250 |
JH12-48W | 12 | 14 | 151 | 5.94 | 98 | 3.86 | 94 | 3.70 | 100 | 3.94 | 3.95 | 8.70 | F250 |
JH12-51W | 12 | 14 | 151 | 5.94 | 98 | 3.86 | 94 | 3.70 | 100 | 3.94 | 3.70 | 8.16 | F250 |
JH12-88W | 12 | 22 | 181 | 7.13 | 76 | 3.0 | 167 | 6.57 | 167 | 6.57 | 5.85 | 12.90 | M5 |
JH12-88WL | 12 | 22 | 181 | 7.13 | 76 | 3.0 | 167 | 6.57 | 167 | 6.57 | 5.80 | 12.80 | L1 |
JH12-102W | 12 | 28 | 175 | 6.89 | 166 | 6.54 | 125 | 4.92 | 125 | 4.92 | 8.55 | 18.85 | M5 |
JH12-110W | 12 | 24 | 165 | 6.50 | 125 | 4.92 | 175 | 6.89 | 175 | 6.89 | 8.90 | 19.62 | M6 |
JH12-320W | 12 | 85 | 260 | 10.24 | 168 | 6.61 | 210 | 8.27 | 210 | 8.27 | 25.0 | 55.10 | M6 |
JH12-390W | 12 | 95 | 307 | 12.09 | 168 | 6.61 | 211 | 8.31 | 214 | 7.43 | 31.0 | 68.30 | M8 |
JH12-410W | 12 | 110 | 330 | 12.99 | 171 | 6.73 | 217 | 8.54 | 220 | 8.66 | 32.0 | 70.54 | M8 |
JH12-530W | 12 | 145 | 336 | 13.23 | 172 | 6.77 | 279 | 10.98 | 279 | 10.98 | 44.0 | 97.0 | M8 |
JH12-580W | 12 | 155 | 336 | 12.23 | 172 | 6.77 | 279 | 10.98 | 279 | 10.98 | 45.5 | 100.3 | M8 |
JH12-700W | 12 | 210 | 522 | 20.55 | 240 | 9.45 | 219 | 8.62 | 222 | 8.74 | 61.5 | 100.3 | M8 |
Capacity range:16w-850w
Voltage class-6V/12V
Long design life (25℃):8-15 years
Low self-discharge rate:≤ 3%/month
High sealed reaction efficiency: ≥99%
Wide operation temperature range:- 20℃-60℃
Structure compact design, shorter internal connectors between cells. thus low internal resistance
Plate: Pasted flat type with patent high rate formula of AM
Terminal: two or more types of terminals are convenient for the selection
Safety valve: flame filter is equipped with a safety valve system
Separator: using an improved AGM separator, makes lower resistance and higher assembling pressure to increase deep cycle life.
Battery case: made of high strength ABS(UL94-HB) and UL94-V0 is optional
Terminal sealing: double sealing technic (mechanical + epoxy glue)
UPS/EPS, Electric Tools, Toys, Medical, wheelchairs, and so on.